Fan coil units are ideal end products for central air conditioning, widely used in hotels, office buildings, hospitals, commercial and residential areas, and research institutions. It is understood that in order to meet the design requirements of different occasions. Fan coil units should be install
Brushless DC motors are becoming increasingly popular in various industries due to their low noise operation and energy efficiency features. In this article, we will explore the benefits of low noise in brushless DC motors, as well as the energy efficiency features that make them a preferred choice for many applications.
When it comes to maintaining a comfortable room temperature, the 4-Way Cassette Unit stands out as a top choice for many homeowners and businesses. In this article, we will explore the numerous advantages that this innovative HVAC system offers in terms of room temperature control.
High wall mounted units have become increasingly popular in the market due to their energy efficiency and quiet operation. In this article, we will explore the key features that make these units stand out in terms of energy efficiency, including their ability to save on electricity costs and reduce carbon footprint. Additionally, we will delve into the innovative noise reduction technology that ensures a peaceful environment while the unit is in operation.
Are you considering installing a high wall mounted unit but wondering about its power consumption? In this article, we will explore the various factors that can affect the power consumption of these units, as well as the benefits they offer in terms of energy efficiency. Additionally, we will provide you with some practical tips on how to further reduce power consumption when using high wall mounted units.
In today's fast-paced world, efficiency and convenience are key factors in any industry. When it comes to installing water valves, integrating them into existing systems can provide a wide range of benefits. From streamlining the installation process to improving overall functionality, the advantages of water valve integration are numerous.
In today's digital age, the use of digital display panels has become increasingly prevalent in enhancing user experience across various industries. From retail stores to airports, understanding the technology behind these panels is crucial for businesses looking to stay ahead of the curve. By utilizing digital display panels, businesses can create engaging and interactive experiences for their customers, ultimately leading to increased brand loyalty and customer satisfaction.
Condensate leakage can be a common issue with traditional HVAC systems, leading to potential damage and inefficiencies. However, with the advancements in technology, 4-Way Cassette Units have emerged as a solution to effectively prevent condensate leakage. Through innovative design features such as improved drainage systems and advanced sensors, these units offer a reliable and efficient cooling solution for both residential and commercial spaces.
First, the definition of two and three lines of the electric valve1. The second line of the electric valve: the two wires of the electric valve are the control signal input line and the power cord.2. Three lines of the electric valve: the three lines of the electric valve are respectively the contro
In the air conditioning system, fan coil is a common hot and cold water heat exchanger, mainly used in indoor air conditioning systems. The three-way valve is one of the important components in the air conditioning system, which is used to control the flow direction and flow of hot and cold water. T
In the world of industrial equipment and electronics, achieving quiet operation is often a top priority for manufacturers. One key component that can greatly contribute to this goal is the integration of cross flow fans. In this article, we will explore the benefits of cross flow fan integration, including improved airflow and reduced noise levels. We will also discuss important factors to consider when integrating cross flow fans, such as size, power consumption, and installation requirements.
Are you looking to improve the air circulation in your home or office? One way to achieve this is through the use of the auto swing feature in your air conditioning unit. In this article, we will explore the benefits of this innovative feature, including how it enhances comfort and efficiency, as we
Are you considering incorporating ultra thin type units into your interior design but unsure if they will complement your style? In this article, we will explore the benefits of ultra thin type units, discuss key factors to consider for compatibility with different interior styles, and present case studies showcasing how these sleek units can seamlessly blend in various design aesthetics.
In the world of marketing, understanding the concept of Host Linkage Function is crucial for businesses looking to optimize convenience and control in their operations. From its features to best practices for utilization, this article delves into the intricacies of Host Linkage Function, providing valuable insights for marketers seeking to leverage this function effectively.
The central air conditioning system consists of three parts: air ducts, air duct accessories and components, and end equipment and components of the air conditioning system.
Aluminum zinc plates have become increasingly popular in various industries due to their numerous benefits and applications. In this article, we will explore the advantages of using aluminum zinc plates, such as their exceptional durability and resistance to corrosion. We will also delve into the wi
The overflow of condensate from fan coil units is a common malfunction of centralized air conditioning systems in summer, which often occurs in hot and humid weather and can cause unnecessary damage to air-conditioned rooms.
Availability: | |
---|---|
Quantity: | |
Features
1. 75pa~30pa static pressure, long distance air supply
2. Integrated models 1020~2720m³/h
3. E-heater in optional
4 use DC brushless motor
5 Fresh air can be input from outside
Our advantages
1 Classical elegant design. Aluminized zinc plate galvanized sheet, beautiful appearance. High corrosion resistance.
2 Big diameter fan, big air volume, low noise
3 Circular air duct interface is optional. Which can reduce the installation cost
Product Applications
The medium static pressure ducted type fan coil unit suitable for installation environments that require a certain length of air supply. It can connect air ducts to supply air to every place that needs it.
TAIZHOU MECO REFRIGERATION EQUIPMENT Co.,Ltd | ||||||||
Performance of high static pressure duct type fan coil unit(MAW series,DC motor ,2 pipe system) | ||||||||
model | unit | DC-MFP-102MAW | DC-MFP-136MAW | DC-MFP-170MAW | DC-MFP-204MAW | DC-MFP-238MAW | DC-MFP-272MAW | |
High speed | m3/h | 1020 | 1360 | 1700 | 2040 | 2380 | 2720 | |
Low speed | m3/h | 360 | 480 | 600 | 720 | 840 | 960 | |
Cooling capacity | High speed kW | TH | 6.6 | 8.2 | 10.2 | 11.9 | 13.9 | 15.1 |
SH | 5 | 6.2 | 7.7 | 8.9 | 10.4 | 11.3 | ||
Low speed kW | TH | 2.8 | 3.4 | 4.3 | 5 | 5.8 | 6.3 | |
SH | 2 | 2.5 | 3.1 | 3.6 | 4.2 | 4.6 | ||
Heating capacity | High speed kW | 10.6 | 13.2 | 16.4 | 19.2 | 22.4 | 24.3 | |
Low speed kW | 4.5 | 5.5 | 6.9 | 8.1 | 9.3 | 10.1 | ||
Noise | dB(A) | 48 | 50 | 54 | 56 | 58 | 60 | |
Water volume | m3/h | 1.13 | 1.4 | 1.74 | 2.03 | 2.37 | 2.58 | |
Static pressure | Pa | 75 | 75 | 75 | 75 | 75 | 75 | |
Water pressure dropping | kPa | 25 | 30 | 32 | 35 | 40 | 55 | |
fan | type | double inlet forward-curve centrifugal fan | ||||||
quantity | 2 | 3 | 4 | |||||
Motor | type | DC brushless motor | ||||||
quantity | 1 | 1 | 2 | 2 | 2 | 2 | ||
power supply | 220V~ 50Hz 1Ph | |||||||
power input(w) | 110 | 155 | 200 | 230 | 270 | 310 | ||
Coil | type | Copper tube coat aluminum fin | ||||||
working pressure | 1.6MPa | |||||||
Pipe connection | water inlet | 3/4" | ||||||
water outlet | 3/4" | |||||||
water drainage | 3/4" | |||||||
dimension(mm) | 1090*624*275 | 1090*624*275 | 1350*624*275 | 1350*624*275 | 1610*624*275 | 1610*624*275 | ||
net weight(kg) | ||||||||
testing condition: | ||||||||
2 PIPE SYSTEM | ||||||||
REFERENCE CONDITIONS | ||||||||
Cooling nominal condition: | ||||||||
indoor air temperature:27℃/19.5℃ DB/WB | ||||||||
water temperature: 7℃/12℃, at maximum speed | ||||||||
Heating nominal condit | ||||||||
indoor air temperature: 21℃/15℃ DB/WB | ||||||||
water inlet temperature: 60℃, at maximum speed, | ||||||||
with the same water flow as in cooling. |
Features
1. 75pa~30pa static pressure, long distance air supply
2. Integrated models 1020~2720m³/h
3. E-heater in optional
4 use DC brushless motor
5 Fresh air can be input from outside
Our advantages
1 Classical elegant design. Aluminized zinc plate galvanized sheet, beautiful appearance. High corrosion resistance.
2 Big diameter fan, big air volume, low noise
3 Circular air duct interface is optional. Which can reduce the installation cost
Product Applications
The medium static pressure ducted type fan coil unit suitable for installation environments that require a certain length of air supply. It can connect air ducts to supply air to every place that needs it.
TAIZHOU MECO REFRIGERATION EQUIPMENT Co.,Ltd | ||||||||
Performance of high static pressure duct type fan coil unit(MAW series,DC motor ,2 pipe system) | ||||||||
model | unit | DC-MFP-102MAW | DC-MFP-136MAW | DC-MFP-170MAW | DC-MFP-204MAW | DC-MFP-238MAW | DC-MFP-272MAW | |
High speed | m3/h | 1020 | 1360 | 1700 | 2040 | 2380 | 2720 | |
Low speed | m3/h | 360 | 480 | 600 | 720 | 840 | 960 | |
Cooling capacity | High speed kW | TH | 6.6 | 8.2 | 10.2 | 11.9 | 13.9 | 15.1 |
SH | 5 | 6.2 | 7.7 | 8.9 | 10.4 | 11.3 | ||
Low speed kW | TH | 2.8 | 3.4 | 4.3 | 5 | 5.8 | 6.3 | |
SH | 2 | 2.5 | 3.1 | 3.6 | 4.2 | 4.6 | ||
Heating capacity | High speed kW | 10.6 | 13.2 | 16.4 | 19.2 | 22.4 | 24.3 | |
Low speed kW | 4.5 | 5.5 | 6.9 | 8.1 | 9.3 | 10.1 | ||
Noise | dB(A) | 48 | 50 | 54 | 56 | 58 | 60 | |
Water volume | m3/h | 1.13 | 1.4 | 1.74 | 2.03 | 2.37 | 2.58 | |
Static pressure | Pa | 75 | 75 | 75 | 75 | 75 | 75 | |
Water pressure dropping | kPa | 25 | 30 | 32 | 35 | 40 | 55 | |
fan | type | double inlet forward-curve centrifugal fan | ||||||
quantity | 2 | 3 | 4 | |||||
Motor | type | DC brushless motor | ||||||
quantity | 1 | 1 | 2 | 2 | 2 | 2 | ||
power supply | 220V~ 50Hz 1Ph | |||||||
power input(w) | 110 | 155 | 200 | 230 | 270 | 310 | ||
Coil | type | Copper tube coat aluminum fin | ||||||
working pressure | 1.6MPa | |||||||
Pipe connection | water inlet | 3/4" | ||||||
water outlet | 3/4" | |||||||
water drainage | 3/4" | |||||||
dimension(mm) | 1090*624*275 | 1090*624*275 | 1350*624*275 | 1350*624*275 | 1610*624*275 | 1610*624*275 | ||
net weight(kg) | ||||||||
testing condition: | ||||||||
2 PIPE SYSTEM | ||||||||
REFERENCE CONDITIONS | ||||||||
Cooling nominal condition: | ||||||||
indoor air temperature:27℃/19.5℃ DB/WB | ||||||||
water temperature: 7℃/12℃, at maximum speed | ||||||||
Heating nominal condit | ||||||||
indoor air temperature: 21℃/15℃ DB/WB | ||||||||
water inlet temperature: 60℃, at maximum speed, | ||||||||
with the same water flow as in cooling. |